Low Pressure AODD Pump Air Operated Diaphragm Waste Oil Pump 70m Maximum Lift

Ask Latest Price
Place of Origin :China
Brand Name :BSK
Model Number :BSKA25AL-P99-A
MOQ :10 Unit(s)
Price :Negotiable
Payment Terms :FOB T/T
Supply Ability :1000 Unit(s) Per Month
Guarantee :one year
production name :air powered liquid pump
Maximum lift :70m
Weight :12.3kg
Maximum particle size :3mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Low Pressure Pharmacy Membrane Pumps Submersible Diaphragm Pump

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

Item Description Unit Reference Figure
1 Maximum air inlet pressure Mpa 0.83
2 Maximum flow rate 1/Min 192
3 Maximum lift M 70
4 Maximum outlet pressure Mpa 0.83
5 Maximum particle size mm 3
6 Weight kg 12.3
7 Noise level db <70

General Description

The diaphragm pump offers high volume delivery even at low air pressure and a b road range of material compatibility options available.Refer to the model and option chart.The pump is provided with the modularized air motor and fluid section.

The air operated diaphragm pump alternately generates the intake fluid pressure and positive fluid pressure in the fluid chamber by using the pressure difference in the air chamber. The ball valve can ensure the forward flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres -sure and will stop cycling once maximum line pressure is reached (dis -pensing device closed) and will resume pumping as needed.

Application

1, Poisonous, combustible and volatilizable liquids.
2, Strong acid, strong alkali liquids with corrosion
3, Tanker truck, bilk plant, load and unload of oil products
4, Pickle, fruit pulp, mashed potatoes, chocolates, etc
5, Paint, rubber, pigment and adhesives
6, Various ceramic pulp, grouting, mortar and slurry
7, Various latex, organic solvents, stuffing
8, Stripping of oil carrier (pump dirty water and residual oil)
9, Common hop, thin paste of yeast power, syrup and molasses
10, Special liquid

Specifications

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP

A 2 5 X X - X X X - X (model selection)

Form of pipe mouth:A-BSP B-NPT(F) C-Flange

Diaphragm material:9 – Santoprene H – Hytrel T - PTFE/Santoprene

Ball material:9 -Santoprene H – Hytre T – PTFE A - Acetal

Ball seat material:P/K –Polypropylene/Kynoar SS –Stainless Steel

Pump material: SS –Stainless Steel AL –Aluminum Alloy CI- Carbon Steel P/K –Polypropylene/Kynoar

Maximum Applied Temperature Limits (diaphragm / ball / seal material)

Acetal ···············································40°- 150°F (4.4- 65.5°C)

Santoprene··········································-40°- 225°F (-40°- 107.2°C) ·················································40°- 220°F (4.4°- 104°C) Nitrile·················································10°- 180°F (-12°- 82°C) Viton···················································-40°- 350°F (-40°-176.6°C) Hytrel··················································-20°-150°F (-12°- 93°C) Kynar····················································10°-200°F (-28.9°- 65.5°C) Polypropylene········································132°- 175°F (0-79.4°C)

1” Flow diagram

Low Pressure AODD Pump Air Operated Diaphragm Waste Oil Pump 70m Maximum Lift

Requirements for Air and Lubrication

Low Pressure AODD Pump Air Operated Diaphragm Waste Oil Pump 70m Maximum LiftEXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage.

  • A filter capable of filtering out particles larger than 50 microns should be used on the air supply. There is no lubrication required other than the “O” ring lubricant which is applied during assembly or repair.
  • If lubricated air is present, make sure that it is compatible with the “O” rings and seals in the air motor section of the pump.


OPERATING INSTRUCTIONS

  • Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
  • Disconnect the air supply from the pump if it is to be inactive for a few hours.
  • The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
  • When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
  • Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.